RESEARCH / DISCOVERY
← Back to the library

An initial experience with intraoperative O-Arm for deep brain stimulation surgery: can it replace post-operative MRI?

An initial experience with intraoperative O-Arm for deep brain stimulation surgery: can it replace post-operative MRI?

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Granada, ES · Author affiliation

Department of Neurosurgery, Virgen de Las Nieves University Hospital, C/ Dr. Muñoz Fernández, No 1, 6B, 18012, Granada, Spain. mjkatati@hotmail.com.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Deep brain stimulation (DBS) is used to treat movement disorders, severe psychiatric disorders, and neuropathic pain, among other diseases. Advanced neuroimaging techniques allow direct or indirect localization of the target site, which is verified in many centers by the intraoperative recording of unitary neuronal activity. Intraoperative image acquisition technology (e.g., O-Arm) is increasingly used for accurate electrode positioning throughout the surgery. The aim of our study is to analyze the initial experience of our team in the utilization of O-Arm for planning DBS and monitoring its precision and accuracy throughout the procedure. The study included 13 patients with movement disorders. All underwent DBS with the intraoperative O-arm image acquisition system (iCT) and Medtronic StealthStation S7 cranial planning system, placing a total of 25 electrodes. For each patient, we calculated the difference between real and theoretic x, y, z coordinates, using the paired Student's t test to evaluate absolute and directional differences and the one-sample Student's t test to analyze differences in Euclidean distances. No statistically significant differences were found in absolute, directional, or Euclidean distances between intended and actual x, y, and z coordinates, based on iCT scan. Our experience confirms that utilization of the O-Arm system in DBS provides accurate and precise verification of electrode placements throughout the procedure. Recent studies found no significant differences between iCT and postoperative MRI, the current gold standard. Further prospective studies are warranted to test the elimination of postoperative MRI when this system is used.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE