RESEARCH / DISCOVERY
← Back to the library

Simultaneous determination of FLZ and its metabolite (M1) in human plasma and urine by UHPLC-MS/MS: Application to a pharmacokinetic study.

Simultaneous determination of FLZ and its metabolite (M1) in human plasma and urine by UHPLC-MS/MS: Application to a pharmacokinetic study.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Beijing, CN · Author affiliation

Clinical Pharmacology Research Center, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, 100032, PR China; Beijing Key Laboratory of Clinical PK and PD Investigation for Innovative Drugs, PR China.
Location evidence

CN · Author affiliation · country only

Hebei Yiling Pharmaceutical Co., Ltd., Hebei, 050035, PR China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

FLZ is a novel anti-Parkinson's disease candidate drug. The main active metabolite is FLZ O-dealkylation (M1) in preclinical studies. A reliable ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) quantitation method was developed for the simultaneous determination of FLZ and M1 with low limits of quantitation in human plasma (0.1 ng/mL) and urine (0.5 ng/mL). The plasma and urine samples were both purified by full-automatic solid phase extraction (SPE) method with ensured high extraction recovery and little matrix effect for both analytes, and then separated on a BEH C18 column (2.1 × 50 mm, 1.7 μm). Detection and quantification were performed using an electrospray ionization (ESI) source in positive mode by multiple reaction monitoring (MRM). The precursor to product ion transitions were monitored at m/z 450.3+→313.2+ for FLZ, m/z 436.3+→299.1+ for M1, m/z 462.6+→142.0+ for [D12]-FLZ (internal standard of FLZ) and m/z 447.2+→125.2+ for [D11]-M1 (internal standard of M1), respectively. This method showed good linearity, accuracy, precision and stability in the range of 0.1-100 ng/mL in plasma and 0.5-500 ng/mL in urine of two analytes. Finally, the developed method was successfully applied to a pharmacokinetic research in Chinese healthy volunteers after oral administration of FLZ tablets.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE