Maximising coverage of brain structures using controlled reflux, convection-enhanced delivery and the recessed step catheter.

Maximising coverage of brain structures using controlled reflux, convection-enhanced delivery and the recessed step catheter.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Cardiff, GB · Author affiliation

School of Engineering, Queen's Building, Cardiff University, The Parade, Cardiff CF24 3AA, UK; Functional Neurosurgery Research Group, University of Bristol, School of Clinical Sciences, Learning & Research Building, Southmead Hospital, UK; Neurological Applications Department, Renishaw PLC, New Mills, Wotton-Under-Edge, Gloucestershire, GL12, UK.
Location evidence

Bristol, GB · Author affiliation

School of Engineering, Queen's Building, Cardiff University, The Parade, Cardiff CF24 3AA, UK; Functional Neurosurgery Research Group, University of Bristol, School of Clinical Sciences, Learning & Research Building, Southmead Hospital, UK; Neurological Applications Department, Renishaw PLC, New Mills, Wotton-Under-Edge, Gloucestershire, GL12, UK.
Location evidence

New Mills, GB · Author affiliation

School of Engineering, Queen's Building, Cardiff University, The Parade, Cardiff CF24 3AA, UK; Functional Neurosurgery Research Group, University of Bristol, School of Clinical Sciences, Learning & Research Building, Southmead Hospital, UK; Neurological Applications Department, Renishaw PLC, New Mills, Wotton-Under-Edge, Gloucestershire, GL12, UK.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: The design and use of convection-enhanced delivery catheters remains an active field as clinical trials have highlighted suboptimal distribution as a contributory factor to the failure of those studies. Recent studies indicate limitations and challenges in achieving target coverage using conventional point source delivery. NEW METHOD: The recessed step catheter(RSC), developed by this group, does not function as a point source delivery device, but instead uses 'controlled reflux' of the infusate to a flow inhibiting recess feature. Here we investigate a range of clinically useful step lengths in agarose gel and investigate proof-of-principle in vivo(n = 5). Infusion morphology was characterised in terms of length, width and distribution volume over a range of flow rates. RESULTS: For a fixed infusion volume, increases in catheter step length strongly correlated with increases in the length and volume of distribution (r>0.90, p < 0.001) whilst there were small reductions in the width of distribution (r<-0.62, p < 0.001). Step lengths below 6 mm produced spherical distributions while steps above 12 mm produced elongated distributions. Increasing peak flow rates resulted in significant reductions in distribution volume at each step length, and an increased risk of reflux beyond the step. Modifications to the infusion morphology using changes in step length were confirmed in vivo. CONCLUSIONS: The combination of the recessed step and the ability to adjust the step length with this catheter design make it highly suitable for tailoring the distribution volume of the infusate to meet specific morphological target volumes in the brain.