RESEARCH / DISCOVERY
← Back to the library

[A mechanical impedance-based measurement system for quantifying Parkinsonian rigidity].

[A mechanical impedance-based measurement system for quantifying Parkinsonian rigidity].

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

CN · Author affiliation · country only

Quanzhou Institute of Equipment Manufacturing, Haixi Institutes, Chinese Academy of Sciences, Jinjiang, Fujian 362200, P.R.China.
Location evidence

Taiyuan, CN · Author affiliation

Quanzhou Institute of Equipment Manufacturing, Haixi Institutes, Chinese Academy of Sciences, Jinjiang, Fujian 362200, P.R.China;School of Electrical and Control Engineering, North University of China, Taiyuan 030051, P.R.China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

At present the parkinsonian rigidity assessment depends on subjective judgment of neurologists according to their experience. This study presents a parkinsonian rigidity quantification system based on the electromechanical driving device and mechanical impedance measurement method. The quantification system applies the electromechanical driving device to perform the rigidity clinical assessment tasks (flexion-extension movements) in Parkinson's disease (PD) patients, which captures their motion and biomechanical information synchronously. Qualified rigidity features were obtained through statistical analysis method such as least-squares parameter estimation. By comparing the judgments from both the parkinsonian rigidity quantification system and neurologists, correlation analysis was performed to find the optimal quantitative feature. Clinical experiments showed that the mechanical impedance has the best correlation (Pearson correlation coefficient r = 0.872, P < 0.001) with the clinical unified Parkinson's disease rating scale (UPDRS) rigidity score. Results confirmed that this measurement system is capable of quantifying parkinsonian rigidity with advantages of simple operation and effective assessment. In addition, the mechanical impedance can be adopted to help doctors to diagnose and monitor parkinsonian rigidity objectively and accurately.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE