RESEARCH / DISCOVERY
← Back to the library

Successful detection of postoperative improvement of dynamic sagittal balance with a newly developed three-dimensional gait motion analysis system in a patient with iatrogenic flatback syndrome: A case report.

Successful detection of postoperative improvement of dynamic sagittal balance with a newly developed three-dimensional gait motion analysis system in a patient with iatrogenic flatback syndrome: A case report.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Tsukuba, JP · Author affiliation

Department of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575, Japan; Division of Regenerative Medicine for Musculoskeletal System, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575, Japan. Electronic address: kmiura@tsukuba-seikei.jp.
Location evidence

Ibaraki, JP · Author affiliation

Department of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575, Japan; Division of Regenerative Medicine for Musculoskeletal System, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575, Japan. Electronic address: kmiura@tsukuba-seikei.jp.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

A 75-year-old Japanese woman with Parkinson's disease complained of lower back pain and gait disturbance because of iatrogenic flatback syndrome. The preoperative global spinal parameters were as follows: C7SVA, 168 mm; TK, 52°; LL, -0.8°; PI, 57°; PT, 55°; TPA, 60°. We performed 3D gait analysis using a VICON System and calculated the dynamic SVA. Preoperatively, her flexion deformity gradually progressed during walking. The dynamic parameters gradually increased as follows: thoracic SVA, 216-241 mm; lumbar SVA, 53-69 mm; spinal SVA, 270-311 mm. We performed two-stage corrective surgery. Her lower back pain and gait disturbance significantly improved. The postoperative global spinal parameters were as follows: C7SVA, 1 mm; TK, 47°; LL, 61°; PI, 52°; PT, 20°; TPA, 13°. Dynamic SVA detected by our 3D gait analysis using VICON were as follows: thoracic SVA, 128 mm; lumbar SVA, 4.9 mm; and spinal SVA, 133 mm. The postoperative dynamic SVA did not change during walking. This is the first report of a patient with iatrogenic flatback syndrome whose postoperative improvement of dynamic spinal sagittal alignment was successfully detected with a newly developed 3D gait analysis system that enabled us to analyze a dynamic change of SVA based on the patient's actual walking with a continuous long-distance gait. Our 3D gait analysis has potential usefulness for evaluating postoperative sagittal balance for iatrogenic flatback syndrome.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE