RESEARCH / DISCOVERY
← Back to the library

A Kinematic Sensor and Algorithm to Detect Motor Fluctuations in Parkinson Disease: Validation Study Under Real Conditions of Use.

A Kinematic Sensor and Algorithm to Detect Motor Fluctuations in Parkinson Disease: Validation Study Under Real Conditions of Use.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Sant Pere de Ribes, ES · Author affiliation

Research Department, Consorci Sanitari del Garraf, Sant Pere de Ribes, Spain.
Location evidence

Vilanova i la Geltrú, ES · Author affiliation

Technical Research Centre for Dependency Care and Autonomous Living, Universitat Politcnica de Catalunya, Vilanova i la Geltru, Spain.
Location evidence

Barcelona, ES · Author affiliation

Sense4Care, Barcelona, Spain.
Location evidence

Madrid, ES · Author affiliation

Department of Neurology, Hospital Universitario 12 de Octubre, Madrid, Spain.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: A new algorithm has been developed, which combines information on gait bradykinesia and dyskinesia provided by a single kinematic sensor located on the waist of Parkinson disease (PD) patients to detect motor fluctuations (On- and Off-periods). OBJECTIVE: The goal of this study was to analyze the accuracy of this algorithm under real conditions of use. METHODS: This validation study of a motor-fluctuation detection algorithm was conducted on a sample of 23 patients with advanced PD. Patients were asked to wear the kinematic sensor for 1 to 3 days at home, while simultaneously keeping a diary of their On- and Off-periods. During this testing, researchers were not present, and patients continued to carry on their usual daily activities in their natural environment. The algorithm's outputs were compared with the patients' records, which were used as the gold standard. RESULTS: The algorithm produced 37% more results than the patients' records (671 vs 489). The positive predictive value of the algorithm to detect Off-periods, as compared with the patients' records, was 92% (95% CI 87.33%-97.3%) and the negative predictive value was 94% (95% CI 90.71%-97.1%); the overall classification accuracy was 92.20%. CONCLUSIONS: The kinematic sensor and the algorithm for detection of motor-fluctuations validated in this study are an accurate and useful tool for monitoring PD patients with difficult-to-control motor fluctuations in the outpatient setting.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE