RESEARCH / DISCOVERY
← Back to the library

Characterization of the stimulus waveforms generated by implantable pulse generators for deep brain stimulation.

Characterization of the stimulus waveforms generated by implantable pulse generators for deep brain stimulation.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Ann Arbor, US · Author affiliation

Center for Neurological Restoration, Cleveland Clinic, Cleveland, OH, USA; Research Service, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA; Biointerfaces Institute, University of Michigan, Ann Arbor, MI, USA. Electronic address: lempka@umich.edu.
Location evidence

US · Author affiliation · country only

Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVE: To determine the circuit elements required to theoretically describe the stimulus waveforms generated by an implantable pulse generator (IPG) during clinical deep brain stimulation (DBS). METHODS: We experimentally interrogated the Medtronic Activa PC DBS IPG and defined an equivalent circuit model that accurately captured the output of the IPG. We then compared the detailed circuit model of the clinical stimulus waveforms to simplified representations commonly used in computational models of DBS. We quantified the errors associated with these simplifications using theoretical activation thresholds of myelinated axons in response to DBS. RESULTS: We found that the detailed IPG model generated substantial differences in activation thresholds compared to simplified models. These differences were largest for bipolar stimulation with long pulse widths. Average errors were ∼3 to 24% for voltage-controlled stimulation and ∼2 to 11% for current-controlled stimulation. CONCLUSIONS: Our results demonstrate the importance of including basic circuit elements (e.g. blocking capacitors, lead wire resistance, electrode capacitance) in model analysis of DBS. SIGNIFICANCE: Computational models of DBS are now commonly used in academic research, industrial technology development, and in the selection of clinical stimulation parameters. Incorporating a realistic representation of the IPG output is necessary to improve the accuracy and utility of these clinical and scientific tools.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE