A new enzyme-linked immunosorbent assay for neurofilament light in cerebrospinal fluid: analytical validation and clinical evaluation.
A new enzyme-linked immunosorbent assay for neurofilament light in cerebrospinal fluid: analytical validation and clinical evaluation.
Where did the research take place?
Possible study sites were matched from the text; these need review.
Same, TZ · Possible study site
To date, all recent studies performed in human CSF have used the same enzyme-linked immunosorbent assay (ELISA).Location evidence
Perugia, IT · Author affiliation
Section of Neurology, Department of Medicine, Santa Maria della Misericordia Hospital, University of Perugia, Perugia, Italy. loregaeta@gmail.com.Location evidence
Gothenburg, SE · Author affiliation
Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry, The Sahlgrenska Academy at the University of Gothenburg, Mölndal, Sweden.Location evidence
Mölndal, SE · Author affiliation
Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry, The Sahlgrenska Academy at the University of Gothenburg, Mölndal, Sweden.Location evidence
Rome, IT · Author affiliation
IRCCS Fondazione Santa Lucia, Rome, Italy.Location evidence
London, GB · Author affiliation
Department of Molecular Neuroscience, UCL Institute of Neurology, Queen Square, London, UK.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: Cerebrospinal fluid (CSF) neurofilament light (NfL) is a reliable marker of neuro-axonal damage in different neurological disorders that is related to disease severity. To date, all recent studies performed in human CSF have used the same enzyme-linked immunosorbent assay (ELISA). To confirm the large body of evidence for NfL, we developed a new ELISA method and here we present the performance characteristics of this new ELISA for CSF NfL in different neurological disorders. METHODS: We produced two monoclonal antibodies (NfL21 and NfL23) directed against the NfL core domain, and developed a novel sandwich ELISA method that we evaluated in patients with: 1) inflammatory demyelinating diseases (IDD; n = 97), including multiple sclerosis (MS; n = 59), clinically isolated syndrome (CIS; n = 32), and radiologically isolated syndrome (RIS; n = 6); 2) Alzheimer's disease (AD; n = 72), including mild cognitive impairment due to AD (MCI-AD, n = 36) and probable AD dementia (AD-dem; n = 36); 3) Parkinson's disease (PD; n = 30); and 4) other neurological noninflammatory and non-neurodegenerative diseases (OND; n = 30). RESULTS: Our new NfL ELISA showed a good analytical performance (inter-plate coefficient of variation (CV) < 13%), with no cross-reactivity with neurofilament medium and heavy (NfM and NfH). With respect to the other available ELISAs, CSF NfL showed the same range of values with a strong correlation (r = 0.9984, p < 0.001) between the two methods. CSF NfL levels were significantly higher in MCI-AD/AD-dem and IDD patients as compared with both PD and OND patients. The highest discriminative power was obtained between IDD and OND patients (area under the curve (AUC) 0.87, 95% confidence interval (CI) 0.80-0.95). Within the IDD group, CSF NfL positively correlated with several clinical and radiological disease severity parameters. CONCLUSIONS: These results show a good analytical performance of the new ELISA for quantification of NfL concentrations in the CSF. CSF NfL is confirmed to be a reliable marker in AD and MS, and a disease-severity marker in MS patients.