RESEARCH / DISCOVERY
← Back to the library

Clinical diagnostic tools for vitamin D assessment.

Clinical diagnostic tools for vitamin D assessment.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

AE · Author affiliation · country only

Department of Chemistry, College of Science, UAE University, Al Ain, United Arab Emirates. Electronic address: altafshah@uaeu.ac.ae.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Vitamin D deficiency has been implicated in a plethora of diseases including rheumatoid arthritis, Parkinson's disease, Alzheimer's disease, and osteoporosis. Deficiency of this vitamin is a global epidemic affecting both developing and developed nations. Within a clinical context, the qualitative and quantitative analysis of vitamin D is therefore vital. The main metabolic markers for assessing vitamin D status in humans are the hydroxylated forms of vitamin D, 25OHD3 and 25OHD2 on account of their long half-lives within the body and excellent stability. An adequate level for healthy individuals of these hydroxylated forms is estimated to be around 20-40ng/ml of blood. There are three main analytical techniques for determining the levels of 25OHD3 and 25OHD2. The first technique is immunoassay-based and can be performed in a rapid, high throughput, automated manner, allowing as many as 240 tests per hour with the duration of each assay as little as 18min. Furthermore, it offers excellent sensitivity with a detection range of 3.4-156ng/ml. A major downside of immunoassays is that they are unable to distinguish between the various forms of vitamin D. While HPLC is a highthroughput low cost instrument it is not a very sensitive technique and cannot quantify the down stream metabolites of vitamin D. The third technique, namely liquid chromatography-mass spectrometry (LC-MS/), provides excellent sensitivity with a wide dynamic range from 0.068pg/ml to 100ng/ml. Additionally, it offers a high level of separation and permits identification of vitamin D-related metabolites. However, a huge limitation with LC/MS/MS is their poor throughput for sample analyses. As yet, there is no analytical technique which combines the fine detection capabilities of LC/MS/MS and the rapid, automated format of immunoassay, for vitamin D analyses. Future attention therefore needs to be given to this area if the current clinical diagnostic tools for vitamin D analysis are to be further improved.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE