RESEARCH / DISCOVERY
← Back to the library

Validation of a Step Detection Algorithm during Straight Walking and Turning in Patients with Parkinson's Disease and Older Adults Using an Inertial Measurement Unit at the Lower Back.

Validation of a Step Detection Algorithm during Straight Walking and Turning in Patients with Parkinson's Disease and Older Adults Using an Inertial Measurement Unit at the Lower Back.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Kiel, DE · Author affiliation

Department of Neurology, University of Kiel, Kiel, Germany.
Location evidence

Tübingen, DE · Author affiliation

Center for Neurology, Department of Neurodegeneration, Hertie Institute for Clinical Brain Research (HIH), University of Tübingen, Tübingen, Germany.
Location evidence

Newcastle upon Tyne, GB · Author affiliation

Institute of Neuroscience/Newcastle University Institute for Ageing, Clinical Ageing Research Unit, Campus for Ageing and Vitality, Newcastle University, Newcastle upon Tyne, United Kingdom.
Location evidence

Stuttgart, DE · Author affiliation

Department of Clinical Gerontology, Robert Bosch Hospital, Stuttgart, Germany.
Location evidence

Amsterdam, NL · Author affiliation

Department of Human Movement Sciences, MOVE Research Institute Amsterdam, VU University Amsterdam, Amsterdam, Netherlands.
Location evidence

Lisbon, PT · Author affiliation

Clinical Pharmacology Unit, Instituto de Medicina Molecular, Lisbon, Portugal.
Location evidence

Móstoles, ES · Author affiliation

HM CINAC, Hospital Universitario HM Puerta del Sur, Móstoles, Madrid, Spain.
Location evidence

Madrid, ES · Author affiliation

HM CINAC, Hospital Universitario HM Puerta del Sur, Móstoles, Madrid, Spain.
Location evidence

Cambridge, US · Author affiliation

Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, United States.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Inertial measurement units (IMUs) positioned on various body locations allow detailed gait analysis even under unconstrained conditions. From a medical perspective, the assessment of vulnerable populations is of particular relevance, especially in the daily-life environment. Gait analysis algorithms need thorough validation, as many chronic diseases show specific and even unique gait patterns. The aim of this study was therefore to validate an acceleration-based step detection algorithm for patients with Parkinson's disease (PD) and older adults in both a lab-based and home-like environment. METHODS: In this prospective observational study, data were captured from a single 6-degrees of freedom IMU (APDM) (3DOF accelerometer and 3DOF gyroscope) worn on the lower back. Detection of heel strike (HS) and toe off (TO) on a treadmill was validated against an optoelectronic system (Vicon) (11 PD patients and 12 older adults). A second independent validation study in the home-like environment was performed against video observation (20 PD patients and 12 older adults) and included step counting during turning and non-turning, defined with a previously published algorithm. RESULTS: A continuous wavelet transform (cwt)-based algorithm was developed for step detection with very high agreement with the optoelectronic system. HS detection in PD patients/older adults, respectively, reached 99/99% accuracy. Similar results were obtained for TO (99/100%). In HS detection, Bland-Altman plots showed a mean difference of 0.002 s [95% confidence interval (CI) -0.09 to 0.10] between the algorithm and the optoelectronic system. The Bland-Altman plot for TO detection showed mean differences of 0.00 s (95% CI -0.12 to 0.12). In the home-like assessment, the algorithm for detection of occurrence of steps during turning reached 90% (PD patients)/90% (older adults) sensitivity, 83/88% specificity, and 88/89% accuracy. The detection of steps during non-turning phases reached 91/91% sensitivity, 90/90% specificity, and 91/91% accuracy. CONCLUSION: This cwt-based algorithm for step detection measured at the lower back is in high agreement with the optoelectronic system in both PD patients and older adults. This approach and algorithm thus could provide a valuable tool for future research on home-based gait analysis in these vulnerable cohorts.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE