RESEARCH / DISCOVERY
← Back to the library

Patients with Parkinson disease present high ambulatory blood pressure variability.

Patients with Parkinson disease present high ambulatory blood pressure variability.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

São Paulo, BR · Author affiliation

School of Physical Education and Sport, University of Sao Paulo, Sao Paulo, Brazil.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Patients with Parkinson disease (PD) present blunted nocturnal blood pressure fall and similar ambulatory blood pressure variability (ABPV) measured by standard deviation (SD) and coefficient of variation (CV) compared with healthy subjects. However, these classical indices of ABPV have limited validity in individuals with circadian blood pressure alterations. New indices, such as the average of daytime and night-time standard deviation weighted by the duration of the daytime and night-time intervals (SDdn ) and the average real variability (ARV), remove the influence of the daytime and the night-time periods on ABPV. This study assessed ABPV by SDdn and ARV in PD. Twenty-one patients with PD (11 men, 66 ± 2 years, stages 2-3 of modified Hoehn & Yahr) and 21 matched controls without Parkinson disease (9 men, 64 ± 1 years old) underwent blood pressure monitoring for 24 h. ABPV was analysed by 24 h, daytime and night-time SD and CV, and by the SDdn and ARV. Systolic/diastolic 24-h and night-time SD and CV were similar between the patients with PD and the controls. The patients with PD presented higher daytime systolic/diastolic CV and SD than the controls (10·4 ± 0·9/12·3 ± 0·8 versus 7·0 ± 0·3/9·9 ± 0·5%, P<0·05; 12·6 ± 1·0/9·1 ± 0·5 versus 8·6 ± 0·4/7·5 ± 0·3 mmHg, P<0·05, respectively) as well as higher systolic/diastolic SDdn (10·9 ± 0·8/8·2 ± 0·5 versus 8·2 ± 0·3/7·1 ± 0·2 mmHg, P<0·05, respectively) and ARV (8·8 ± 0·6/6·9 ± 0·3 versus 7·2 ± 0·2/6·0 ± 0·2 mmHg, P<0·05, respectively). In conclusion, patients with PD have higher ABPV than control subjects as assessed by SDd , CVd , SDdn and AVR.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE