RESEARCH / DISCOVERY
← Back to the library

Parkinson's disease patient preference and experience with various methods of DBS lead placement.

Parkinson's disease patient preference and experience with various methods of DBS lead placement.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

San Francisco, US · Author affiliation

Department of Neurology, University of California, San Francisco, CA, USA.
Location evidence

Roanoke, US · Author affiliation

Department of Neurology, University of California, San Francisco, CA, USA; Virginia Tech Carilion School of Medicine, Roanoke, VA, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Physiology-guided deep brain stimulation (DBS) surgery requires patients to be awake during a portion of the procedure, which may be poorly tolerated. Interventional MRI-guided (iMRI) DBS surgery was developed to use real-time image guidance, obviating the need for patients to be awake during lead placement. METHODS: All English-speaking adults with PD who underwent iMRI DBS between 2010 and 2014 at our Center were invited to participate. Subjects completed a structured interview that explored perioperative preferences and experiences. We compared these responses to patients who underwent the physiology-guided method, matched for age and gender. RESULTS: Eighty-nine people with PD completed the study. Of those, 40 underwent iMRI, 44 underwent physiology-guided implantation, and five underwent both methods. There were no significant differences in baseline characteristics between groups. The primary reason for choosing iMRI DBS was a preference to be asleep during implantation due to: 1) a history of claustrophobia; 2) concerns about the potential for discomfort during the awake physiology-guided procedure in those with an underlying pain syndrome or severe off-medication symptoms; or 3) non-specific fear about being awake during neurosurgery. CONCLUSION: Participants were satisfied with both DBS surgery methods. However, identification of the factors associated with a preference for iMRI DBS may allow for optimization of patient experience and satisfaction when choices of surgical methods for DBS implantation are available.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE