Tremor stability index: a new tool for differential diagnosis in tremor syndromes.
Tremor stability index: a new tool for differential diagnosis in tremor syndromes.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Rome, IT · Author affiliation
Neurology Unit, Campus Bio-Medico University of Rome, Via Alvaro del Portillo 200, 00128, Rome, Italy.Location evidence
Oxford, GB · Author affiliation
Nuffield Department of Clinical Neurosciences, University of Oxford, Level 6, West Wing, John Radcliffe Hospital, OX3 9DU, Oxford, UK.Location evidence
Radcliffe, GB · Author affiliation
Nuffield Department of Clinical Neurosciences, University of Oxford, Level 6, West Wing, John Radcliffe Hospital, OX3 9DU, Oxford, UK.Location evidence
Mansfield, GB · Author affiliation
Medical Research Council Brain Network Dynamics Unit, Department of Pharmacology, University of Oxford, Mansfield Road, OX1 3TH, Oxford, UK.Location evidence
DE · Author affiliation · country only
Department of Neurology, University Hospital of Cologne, Kerpener Straße 62, 50924 Cologne, Germany.Location evidence
Taipei, TW · Author affiliation
Department of Neurology and Neuroscience Research Center, Chang Gung Memorial Hospital and University, Taipei, Taiwan.Location evidence
Sevilla, ES · Author affiliation
Unidad de Trastornos del Movimiento, Servicio de Neurología y Neurofisiología Clínica, Instituto de Biomedicina de Sevilla (IBiS), Hospital Universitario Virgen del Rocío/CSIC/Universidad de Sevilla, Seville, Spain.Location evidence
Universidad, ES · Author affiliation
Unidad de Trastornos del Movimiento, Servicio de Neurología y Neurofisiología Clínica, Instituto de Biomedicina de Sevilla (IBiS), Hospital Universitario Virgen del Rocío/CSIC/Universidad de Sevilla, Seville, Spain.Location evidence
Centro, ES · Author affiliation
Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Spain.Location evidence
Graz, AT · Author affiliation
Department of Neurology, Medical University of Graz, Auenbruggerplatz 22, 8036 Graz, Austria.Location evidence
London, GB · Author affiliation
Sobell Department of Motor Neuroscience and Movement Disorders, University College London, Queen Square, WC1N 3BG, London, UK.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
See Vidailhet et al. (doi:10.1093/brain/awx140) for a scientific commentary on this article. Misdiagnosis among tremor syndromes is common, and can impact on both clinical care and research. To date no validated neurophysiological technique is available that has proven to have good classification performance, and the diagnostic gold standard is the clinical evaluation made by a movement disorders expert. We present a robust new neurophysiological measure, the tremor stability index, which can discriminate Parkinson’s disease tremor and essential tremor with high diagnostic accuracy. The tremor stability index is derived from kinematic measurements of tremulous activity. It was assessed in a test cohort comprising 16 rest tremor recordings in tremor-dominant Parkinson’s disease and 20 postural tremor recordings in essential tremor, and validated on a second, independent cohort comprising a further 55 tremulous Parkinson’s disease and essential tremor recordings. Clinical diagnosis was used as gold standard. One hundred seconds of tremor recording were selected for analysis in each patient. The classification accuracy of the new index was assessed by binary logistic regression and by receiver operating characteristic analysis. The diagnostic performance was examined by calculating the sensitivity, specificity, accuracy, likelihood ratio positive, likelihood ratio negative, area under the receiver operating characteristic curve, and by cross-validation. Tremor stability index with a cut-off of 1.05 gave good classification performance for Parkinson’s disease tremor and essential tremor, in both test and validation datasets. Tremor stability index maximum sensitivity, specificity and accuracy were 95%, 95% and 92%, respectively. Receiver operating characteristic analysis showed an area under the curve of 0.916 (95% confidence interval 0.797–1.000) for the test dataset and a value of 0.855 (95% confidence interval 0.754–0.957) for the validation dataset. Classification accuracy proved independent of recording device and posture. The tremor stability index can aid in the differential diagnosis of the two most common tremor types. It has a high diagnostic accuracy, can be derived from short, cheap, widely available and non-invasive tremor recordings, and is independent of operator or postural context in its interpretation.