RESEARCH / DISCOVERY
← Back to the library

Combined use of dopamine transporter imaging (DAT-SPECT) and 123I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy for diagnosing Parkinson's disease.

Combined use of dopamine transporter imaging (DAT-SPECT) and 123I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy for diagnosing Parkinson's disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Ōiso, JP · Author affiliation

Department of Neurology, Tokai University Oiso Hospital, 21-1 Gakkyou, Oiso, Naka-gun 259-0198, Japan. Electronic address: yoshii@is.icc.u-tokai.ac.jp.
Location evidence

Isehara, JP · Author affiliation

Department of Neurology, Tokai University Hospital, 143 Simokasuya, Isehara 259-1193, Japan.
Location evidence

Hiratsuka, JP · Author affiliation

Department of Neurology, Hiratsuka City Hospital, 1-19-1 Minamihara, Hiratsuka 254-0065, Japan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: To examine whether combined use of 123I-FP-CIT dopamine transporter single photon emission computed tomography (DAT-SPECT) and 123I-MIBG myocardial scintigraphy (MIBG) is superior to either modality alone for diagnosing Parkinson's disease (PD). METHODS: Patients with probable PD (n=120) who underwent both DAT-SPECT and MIBG myocardial scintigraphy within short intervals were enrolled. Specific binding ratio (SBR) of DAT-SPECT images and heart-to-mediastinum (H/M) ratio of MIBG images were used as quantitative measures. We classified patients into 4 groups based on SBR value and H/M ratio, or into two groups based on the striatal asymmetry index (SAI) of DAT-SPECT, and examined the clinical features of each group. We also investigated the characteristics of SWEDDs (scans without evidence of dopaminergic deficits) patients. Finally, we calculated the sensitivity and specificity of each method and the combined method. RESULTS: SBR value was significantly correlated with both early and delayed H/M ratio values. Motor complications and hallucinations were observed at high frequency in the group with both lower SBR and H/M ratio, and hallucinations appeared in the group with larger SAI. SWEDDs were observed 8.3% of patients. The sensitivity and specificity of diagnosing PD were 91.7% and 15.0% by SBR of DAT-SPECT, 78.3% and 90.0% by H/M ratio of MIBG uptake, and 74.2% and 95.0% by the combined modalities, respectively. CONCLUSIONS: Combined use of DAT-SPECT and MIBG myocardial scintigraphy increases the specificity of PD diagnosis, and is helpful for understanding the clinical features or predicting complications.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE