Freezing of gait and fall detection in Parkinson's disease using wearable sensors: a systematic review.

Freezing of gait and fall detection in Parkinson's disease using wearable sensors: a systematic review.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Nijmegen, NL · Author affiliation

Radboud university medical center, Donders Institute for Brain, Cognition and Behavior, Nijmegen, The Netherlands. ana.silvadelima@radboudumc.nl.
Location evidence

Brasília, BR · Author affiliation

CAPES Foundation, Ministry of Education of Brazil, Brasília, DF, Brazil. ana.silvadelima@radboudumc.nl.
Location evidence

New York City, US · Author affiliation

Michael J Fox Foundation for Parkinson's Research, New York, USA.
Location evidence

Aston, GB · Author affiliation

Aston University, Birmingham, UK.
Location evidence

Birmingham, GB · Author affiliation

Aston University, Birmingham, UK.
Location evidence

Cambridge, US · Author affiliation

Media Lab, Massachusetts Institute of Technology, Cambridge, USA.
Location evidence

Shizuoka, JP · Author affiliation

Department of Neurology, Juntendo University Shizuoka Hospital, Izunokuni, Shizuoka, Japan.
Location evidence

Izunokuni, JP · Author affiliation

Department of Neurology, Juntendo University Shizuoka Hospital, Izunokuni, Shizuoka, Japan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Despite the large number of studies that have investigated the use of wearable sensors to detect gait disturbances such as Freezing of gait (FOG) and falls, there is little consensus regarding appropriate methodologies for how to optimally apply such devices. Here, an overview of the use of wearable systems to assess FOG and falls in Parkinson's disease (PD) and validation performance is presented. A systematic search in the PubMed and Web of Science databases was performed using a group of concept key words. The final search was performed in January 2017, and articles were selected based upon a set of eligibility criteria. In total, 27 articles were selected. Of those, 23 related to FOG and 4 to falls. FOG studies were performed in either laboratory or home settings, with sample sizes ranging from 1 PD up to 48 PD presenting Hoehn and Yahr stage from 2 to 4. The shin was the most common sensor location and accelerometer was the most frequently used sensor type. Validity measures ranged from 73-100% for sensitivity and 67-100% for specificity. Falls and fall risk studies were all home-based, including samples sizes of 1 PD up to 107 PD, mostly using one sensor containing accelerometers, worn at various body locations. Despite the promising validation initiatives reported in these studies, they were all performed in relatively small sample sizes, and there was a significant variability in outcomes measured and results reported. Given these limitations, the validation of sensor-derived assessments of PD features would benefit from more focused research efforts, increased collaboration among researchers, aligning data collection protocols, and sharing data sets.