RESEARCH / DISCOVERY
← Back to the library

The predictive value of SS-16 in clinically diagnosed Parkinson's disease patients: comparison with (99m)Tc-TRODAT-1 SPECT scans.

The predictive value of SS-16 in clinically diagnosed Parkinson's disease patients: comparison with (99m)Tc-TRODAT-1 SPECT scans.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Shanghai, CN · Author affiliation

Department of Neurology & Institute of Neurology, Ruijin Hospital affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
Location evidence

Royal Oak, US · Author affiliation

Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI 48073 USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Dopamine transporter based imaging has high diagnostic performance in distinguishing patients with Parkinson's disease (PD) from patients with non-Parkinsonian syndromes. Our previous study indicated that the "Sniffin' Sticks" odor identification test (SS-16) acts as a valid instrument for olfactory assessment in Chinese PD patients. The aim of the study was to compare the efficacy of the two methods in diagnosing PD. METHODS: Fifty-two PD patients were involved in this study and underwent single photon emission computed tomography (SPECT) imaging using the labeled dopamine transporter radiotracer (99m)Tc-TRODAT-1 to assess nigrostriatal dopaminergic function. Olfactory function was assessed with the "Sniffin' Sticks" odor identification test (SS-16) in all patients who received DAT-SPECT scanning. Statistical analysis (SPSS version 21) was carried out to determine the diagnostic accuracy of SS-16 as well as its correlation with (99m)Tc-TRODAT-1 SPECT, its positive predictive value (PPV), and negative predictive value (NPV). RESULTS: We identified a negative correlation between SS-16 and DAT SPECT (Kappa = 0.269, p = 0.004). By using the (99m)Tc-TRODAT-1 uptake results as the gold standard, the sensitivity and specificity of SS-16 was 56.8 and 37.5 %, respectively. Furthermore, the negative and positive predictive values were calculated as 13.6 and 83.3 %, respectively. CONCLUSIONS: SS-16 would not be used as a diagnostic tool for early stage PD patients. Negative results of SS-16 would not exclude the diagnosis of PD. Further tests are needed for validation.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE