RESEARCH / DISCOVERY
← Back to the library

Capturing nighttime symptoms in Parkinson disease: Technical development and experimental verification of inertial sensors for nocturnal hypokinesia.

Capturing nighttime symptoms in Parkinson disease: Technical development and experimental verification of inertial sensors for nocturnal hypokinesia.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Bangkok, TH · Author affiliation

Chulalongkorn Center of Excellence for Parkinson Disease & Related Disorders, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand;
Location evidence

TH · Author affiliation · country only

Biomedical Signal Processing Laboratory, National Electronics and Computer Technology Center, Pathumthani, Thailand
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Although nocturnal hypokinesia represents one of the most common nocturnal disabilities in Parkinson disease (PD), it is often a neglected problem in daily clinical practice. We have developed a portable ambulatory motion recorder (the NIGHT-Recorder), which consists of 16-bit triaxial integrated microelectromechanical system inertial sensors that are specifically designed to measure movements, register the position of the body with respect to gravity, and provide information on rotations on the longitudinal axis while lying in bed. The signal processing uses the forward derivative method to identify rolling over and getting out of bed as primary indicators. The prototype was tested on six PD pairs to measure their movements for one night. Using predetermined definitions, 134 movements were captured consisting of rolling over 115 times and getting out of bed 19 times. Patients with PD rolled over significantly fewer times than their spouses (p = 0.03), and the position change was significantly smaller in patients with PD (p = 0.03). Patients with PD rolled over at a significantly slower speed (p = 0.03) and acceleration (p = 0.03) than their spouses. In contrast, patients with PD got out of bed significantly more often than their spouses (p = 0.02). It is technically feasible to develop an easy-to-use, portable, and accurate device that can assist physicians in the assessment of nocturnal movements of patients with PD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE