RESEARCH / DISCOVERY
← Back to the library

Intraoperative MRI for deep brain stimulation lead placement in Parkinson's disease: 1 year motor and neuropsychological outcomes.

Intraoperative MRI for deep brain stimulation lead placement in Parkinson's disease: 1 year motor and neuropsychological outcomes.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

US · Author affiliation · country only

Parkinson's Disease and Movement Disorders Program, Henry Ford Hospital, 6777 West Maple Road, West Bloomfield, MI, 48322, USA. csidiro1@hfhs.org.
Location evidence

Detroit, US · Author affiliation

Department of Neurosurgery, Henry Ford Hospital, 2799 West Grand Blvd, Detroit, MI, 48202, USA.
Location evidence

Royal Oak, US · Author affiliation

William Beaumont Health System, 3601 W 13 Mile Rd, Royal Oak, MI, 48073, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Traditional deep brain stimulation requires intraoperative neurophysiological confirmation of electrode placement. Recently, purely image guided methods are being evaluated as to their clinical efficacy in comparison to surgery using microelectrode recordings. We used the ClearPoint(®) system to place electrodes in both the subthalamic nucleus and globus pallidus internus in patients with advanced Parkinson's disease. Off medication UPDRS scores were assessed before and 1 year after surgery as well as pre- and 1 year post-operative neuropsychological outcomes. Targeting precision was also assessed. Patients implanted in the subthalamic nucleus improved by 46.2 % in their UPDRS scores post-operatively (p = 0.03) whereas the globus pallidus group improved by 41 % (p = 0.06). There were no significant adverse neuropsychological outcomes in either group of patients. Mean radial error for the STN group was 1.2 ± 0.7 mm and for the GPi group 0.8 mm ± 0.3 mm. Image guided DBS using the ClearPoint(®)system has high targeting precision with robust clinical outcomes. Our data are in accord with recent studies using the same or similar technologies and provide a rationale for a large comparative study of image-guided versus microelectrode guided DBS.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE