RESEARCH / DISCOVERY
← Back to the library

Moving average template subtraction to remove stimulation artefacts in EEGs and LFPs recorded during deep brain stimulation.

Moving average template subtraction to remove stimulation artefacts in EEGs and LFPs recorded during deep brain stimulation.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Boston, US · Author affiliation

Division of Newborn Medicine, Boston Children's Hospital, Harvard Medical School, 02115 Boston, MA, USA; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 02129 Cambridge, MA, USA.
Location evidence

Cambridge, US · Author affiliation

Division of Newborn Medicine, Boston Children's Hospital, Harvard Medical School, 02115 Boston, MA, USA; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 02129 Cambridge, MA, USA.
Location evidence

Magdeburg, DE · Author affiliation

Department of Neurology, Otto-von-Guericke University, Leipziger Straße 44, 39120 Magdeburg, Germany; Leibniz Institute for Neurobiology (LIN), Brenneckestr. 6, 39118 Magdeburg, Germany; Deutsches Zentrum für Neurodegenerative Erkrankungen (DZNE), Leipziger Straße 44, 39120 Magdeburg, Germany; Forschungscampus STIMULATE, Sandtorstraße 23, 39106 Magdeburg, Germany; Center for Behavioural Brain Sciences (CBBS), Leipziger Straße 44, 39120 Magdeburg, Germany. Electronic address: Hermann.Hinrichs@med.ovgu.de.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Deep brain stimulation (DBS) is a well established therapy to treat movement disorders such as Parkinson's disease. More recently it has also been discussed as a therapy for certain psychiatric diseases. However, during active DBS the recordings of local field potentials (LFP) and the electroencephalogram (EEG) can be corrupted by substantial spike-type artefacts which need to be removed before any analysis. NEW METHOD: Here, we present a new method that we term ' Moving Average Subtraction' (MAS) that removes DBS artefacts by subtracting adaptive DBS artefact templates from the artefact contaminated data. In particular we have developed a resampling technique which is more efficient than upsampling for a precise reconstruction of the artefact shape without the need to oversample the EEGs. RESULTS: By applying this method we can derive undistorted signals even in case of the low sampling frequencies that are usual in clinical recordings. We applied the new technique to 12 data sets recorded at the surface and in various brain structures [subthalamic nucleus (STN), pedunculo pontine nucleus (PPN), Globus pallidus internus (GPi)] with 7 patients. Our results demonstrate the suppression of artefact related activity at the basic and harmonic frequencies of DBS. COMPARISON WITH EXISTING METHOD(S): The new technique outperforms the non-adaptive template subtraction technique for the removal of high frequency artefact residuals without producing the spectral dips that occur with notch filter approaches. CONCLUSIONS: The new technique facilitates the analysis of higher frequency bands (Gamma activity) in LFPs and EEGs recorded during active DBS.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE