RESEARCH / DISCOVERY
← Back to the library

Dopaminergic-induced dyskinesia assessment based on a single belt-worn accelerometer.

Dopaminergic-induced dyskinesia assessment based on a single belt-worn accelerometer.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Centro, ES · Author affiliation

Centro de Estudios para la Dependencia y la vida Autónoma (CETpD), Universitat Politècnica de Catalunya (UPC), Rambla de l'Exposició, 59, 08800 Vilanova i la Geltrú, Barcelona, Spain. Electronic address: carlos.perez-lopez@upc.edu.
Location evidence

Vilanova i la Geltrú, ES · Author affiliation

Centro de Estudios para la Dependencia y la vida Autónoma (CETpD), Universitat Politècnica de Catalunya (UPC), Rambla de l'Exposició, 59, 08800 Vilanova i la Geltrú, Barcelona, Spain. Electronic address: carlos.perez-lopez@upc.edu.
Location evidence

Barcelona, ES · Author affiliation

Centro de Estudios para la Dependencia y la vida Autónoma (CETpD), Universitat Politècnica de Catalunya (UPC), Rambla de l'Exposició, 59, 08800 Vilanova i la Geltrú, Barcelona, Spain. Electronic address: carlos.perez-lopez@upc.edu.
Location evidence

Galway, IE · Author affiliation

Electrical & Electronic Engineering, School of Engineering & Informatics National University Galway (NUIG), University Rd, Galway, Ireland.
Location evidence

Rome, IT · Author affiliation

Fondazione Santa Lucia, Via Ardeatina, 306, Rome 00142, Italy.
Location evidence

Cusano, IT · Author affiliation

Fondazione Santa Lucia, Via Ardeatina, 306, Rome 00142, Italy; Niccolò Cusano University, via Don Carlo Gnocchi, 3, Rome 00166, Italy.
Location evidence

IL · Author affiliation · country only

Maccabi Healthcare Services, Hamered Street 27, Tel-Aviv 68125, Israel.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: After several years of treatment, patients with Parkinson's disease (PD) tend to have, as a side effect of the medication, dyskinesias. Close monitoring may benefit patients by enabling doctors to tailor a personalised medication regimen. Moreover, dyskinesia monitoring can help neurologists make more informed decisions in patient's care. OBJECTIVE: To design and validate an algorithm able to be embedded into a system that PD patients could wear during their activities of daily living with the purpose of registering the occurrence of dyskinesia in real conditions. MATERIALS AND METHODS: Data from an accelerometer positioned in the waist are collected at the patient's home and are annotated by experienced clinicians. Data collection is divided into two parts: a main database gathered from 92 patients used to partially train and to evaluate the algorithms based on a leave-one-out approach and, on the other hand, a second database from 10 patients which have been used to also train a part of the detection algorithm. RESULTS: Results show that, depending on the severity and location of dyskinesia, specificities and sensitivities higher than 90% are achieved using a leave-one-out methodology. Although mild dyskinesias presented on the limbs are detected with 95% specificity and 39% sensitivity, the most important types of dyskinesia (any strong dyskinesia and trunk mild dyskinesia) are assessed with 95% specificity and 93% sensitivity. CONCLUSION: The presented algorithmic method and wearable device have been successfully validated in monitoring the occurrence of strong dyskinesias and mild trunk dyskinesias during activities of daily living.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE