Dopaminergic-induced dyskinesia assessment based on a single belt-worn accelerometer.
Dopaminergic-induced dyskinesia assessment based on a single belt-worn accelerometer.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Centro, ES · Author affiliation
Centro de Estudios para la Dependencia y la vida Autónoma (CETpD), Universitat Politècnica de Catalunya (UPC), Rambla de l'Exposició, 59, 08800 Vilanova i la Geltrú, Barcelona, Spain. Electronic address: carlos.perez-lopez@upc.edu.Location evidence
Vilanova i la Geltrú, ES · Author affiliation
Centro de Estudios para la Dependencia y la vida Autónoma (CETpD), Universitat Politècnica de Catalunya (UPC), Rambla de l'Exposició, 59, 08800 Vilanova i la Geltrú, Barcelona, Spain. Electronic address: carlos.perez-lopez@upc.edu.Location evidence
Barcelona, ES · Author affiliation
Centro de Estudios para la Dependencia y la vida Autónoma (CETpD), Universitat Politècnica de Catalunya (UPC), Rambla de l'Exposició, 59, 08800 Vilanova i la Geltrú, Barcelona, Spain. Electronic address: carlos.perez-lopez@upc.edu.Location evidence
Galway, IE · Author affiliation
Electrical & Electronic Engineering, School of Engineering & Informatics National University Galway (NUIG), University Rd, Galway, Ireland.Location evidence
Rome, IT · Author affiliation
Fondazione Santa Lucia, Via Ardeatina, 306, Rome 00142, Italy.Location evidence
Cusano, IT · Author affiliation
Fondazione Santa Lucia, Via Ardeatina, 306, Rome 00142, Italy; Niccolò Cusano University, via Don Carlo Gnocchi, 3, Rome 00166, Italy.Location evidence
IL · Author affiliation · country only
Maccabi Healthcare Services, Hamered Street 27, Tel-Aviv 68125, Israel.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: After several years of treatment, patients with Parkinson's disease (PD) tend to have, as a side effect of the medication, dyskinesias. Close monitoring may benefit patients by enabling doctors to tailor a personalised medication regimen. Moreover, dyskinesia monitoring can help neurologists make more informed decisions in patient's care. OBJECTIVE: To design and validate an algorithm able to be embedded into a system that PD patients could wear during their activities of daily living with the purpose of registering the occurrence of dyskinesia in real conditions. MATERIALS AND METHODS: Data from an accelerometer positioned in the waist are collected at the patient's home and are annotated by experienced clinicians. Data collection is divided into two parts: a main database gathered from 92 patients used to partially train and to evaluate the algorithms based on a leave-one-out approach and, on the other hand, a second database from 10 patients which have been used to also train a part of the detection algorithm. RESULTS: Results show that, depending on the severity and location of dyskinesia, specificities and sensitivities higher than 90% are achieved using a leave-one-out methodology. Although mild dyskinesias presented on the limbs are detected with 95% specificity and 39% sensitivity, the most important types of dyskinesia (any strong dyskinesia and trunk mild dyskinesia) are assessed with 95% specificity and 93% sensitivity. CONCLUSION: The presented algorithmic method and wearable device have been successfully validated in monitoring the occurrence of strong dyskinesias and mild trunk dyskinesias during activities of daily living.