RESEARCH / DISCOVERY
← Back to the library

The Effect of Personalization on Smartphone-Based Fall Detectors.

The Effect of Personalization on Smartphone-Based Fall Detectors.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Teruel, ES · Author affiliation

EduQTech, E.U. Politécnica de Teruel, University of Zaragoza, c/Atarazana 2, 44003 Teruel, Spain. ctmedra@unizar.es.
Location evidence

Zaragoza, ES · Author affiliation

EduQTech, E.U. Politécnica de Teruel, University of Zaragoza, c/Atarazana 2, 44003 Teruel, Spain. ctmedra@unizar.es.
Location evidence

Madrid, ES · Author affiliation

Electrical, and Computer Engineering Department, Spanish University for Distant Education (UNED), C/ Juan del Rosal, 12, 28040 Madrid, Spain. mcastro@ieec.uned.es.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

The risk of falling is high among different groups of people, such as older people, individuals with Parkinson's disease or patients in neuro-rehabilitation units. Developing robust fall detectors is important for acting promptly in case of a fall. Therefore, in this study we propose to personalize smartphone-based detectors to boost their performance as compared to a non-personalized system. Four algorithms were investigated using a public dataset: three novelty detection algorithms--Nearest Neighbor (NN), Local Outlier Factor (LOF) and One-Class Support Vector Machine (OneClass-SVM)--and a traditional supervised algorithm, Support Vector Machine (SVM). The effect of personalization was studied for each subject by considering two different training conditions: data coming only from that subject or data coming from the remaining subjects. The area under the receiver operating characteristic curve (AUC) was selected as the primary figure of merit. The results show that there is a general trend towards the increase in performance by personalizing the detector, but the effect depends on the individual being considered. A personalized NN can reach the performance of a non-personalized SVM (average AUC of 0.9861 and 0.9795, respectively), which is remarkable since NN only uses activities of daily living for training.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE