A Validated Smartphone-Based Assessment of Gait and Gait Variability in Parkinson's Disease.
A Validated Smartphone-Based Assessment of Gait and Gait Variability in Parkinson's Disease.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Singapore, SG · Author affiliation
School of Computing, National University of Singapore, Computing 1, 13 Computing Drive, Singapore, 117417, Singapore.Location evidence
Brookline, US · Author affiliation
Department of Neurology, Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, Palmer 127, Boston, MA, 02215, United States of America.Location evidence
Palmer, US · Author affiliation
Department of Neurology, Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, Palmer 127, Boston, MA, 02215, United States of America.Location evidence
Boston, US · Author affiliation
Department of Neurology, Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, Palmer 127, Boston, MA, 02215, United States of America.Location evidence
IL · Author affiliation · country only
Department of Neurology, Beth Israel Deaconess Medical Center and Harvard Medical School, 330 Brookline Avenue, Palmer 127, Boston, MA, 02215, United States of America.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BackgroundA well-established connection exists between increased gait variability and greater fall likelihood in Parkinson's disease (PD); however, a portable, validated means of quantifying gait variability (and testing the efficacy of any intervention) remains lacking. Furthermore, although rhythmic auditory cueing continues to receive attention as a promising gait therapy for PD, its widespread delivery remains bottlenecked. The present paper describes a smartphone-based mobile application ("SmartMOVE") to address both needs.MethodsThe accuracy of smartphone-based gait analysis (utilizing the smartphone's built-in tri-axial accelerometer and gyroscope to calculate successive step times and step lengths) was validated against two heel contact-based measurement devices: heel-mounted footswitch sensors (to capture step times) and an instrumented pressure sensor mat (to capture step lengths). 12 PD patients and 12 age-matched healthy controls walked along a 26-m path during self-paced and metronome-cued conditions, with all three devices recording simultaneously.ResultsFour outcome measures of gait and gait variability were calculated. Mixed-factorial analysis of variance revealed several instances in which between-group differences (e.g., increased gait variability in PD patients relative to healthy controls) yielded medium-to-large effect sizes (eta-squared values), and cueing-mediated changes (e.g., decreased gait variability when PD patients walked with auditory cues) yielded small-to-medium effect sizes-while at the same time, device-related measurement error yielded small-to-negligible effect sizes.ConclusionThese findings highlight specific opportunities for smartphone-based gait analysis to serve as an alternative to conventional gait analysis methods (e.g., footswitch systems or sensor-embedded walkways), particularly when those methods are cost-prohibitive, cumbersome, or inconvenient.