RESEARCH / DISCOVERY
← Back to the library

Development of a liquid chromatography assay for the determination of opicapone and BIA 9-1079 in rat matrices.

Development of a liquid chromatography assay for the determination of opicapone and BIA 9-1079 in rat matrices.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Coimbra, PT · Author affiliation

Laboratory of Pharmacology, Faculty of Pharmacy, University of Coimbra, Pólo das Ciências da Saúde, Azinhaga de Santa Comba, 3000-548, Coimbra, Portugal.
Location evidence

Covilhã, PT · Author affiliation

CICS-UBI - Health Sciences Research Centre, University of Beira Interior, Av. Infante D. Henrique, 6200-506, Covilhã, Portugal.
Location evidence

PT · Author affiliation · country only

Department of Research and Development, BIAL, Av. da Siderurgia Nacional, 4745-457, S. Mamede do Coronado, Portugal.
Location evidence

Porto, PT · Author affiliation

Department of Pharmacology and Therapeutics, Faculty of Medicine, University of Porto, 4200-319, Porto, Portugal.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Opicapone is a novel potent, reversible and purely peripheral third generation catechol-O-methyltransferase inhibitor, currently under clinical trials as an adjunct to levodopa therapy for Parkinson's disease. To support additional nonclinical pharmacokinetic studies, a novel high-performance liquid chromatographic method coupled to a diode array detector (HPLC-DAD) to quantify opicapone and its active metabolite (BIA 9-1079) in rat plasma and tissues (liver and kidney) is herein reported. The analytes were extracted from rat samples through a deproteinization followed by liquid-liquid extraction. Chromatographic separation was achieved in less than 10 min on a reversed-phase C18 column, applying a gradient elution program with 0.05 M monosodium phosphate solution (pH 2.45 ± 0.05) and acetonitrile. Calibration curves were linear (r(2)  ≥ 0.994) within the ranges of 0.04-6.0 µg/mL for both analytes in plasma, 0.04-4.0 µg/mL for opicapone in liver and kidney homogenates, and 0.07-4.0 µg/mL and 0.06-4.0 µg/mL for BIA 9-1079 in liver and kidney homogenates, respectively. The overall intra- and inter-day accuracy ranged from -12.68% to 7.70% and the imprecision values did not exceed 11.95%. This new HPLC-DAD assay was also successfully applied to quantify opicapone and BIA 9-1079 in a preliminary pharmacokinetic study.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE