RESEARCH / DISCOVERY
← Back to the library

Stemless humeral component in reverse shoulder prosthesis in patient with Parkinson�s disease: a case report

Stemless humeral component in reverse shoulder prosthesis in patient with Parkinson�s disease: a case report

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Pisa, IT · Author affiliation

II Orthopedic and Traumatologic Clinic, University of Pisa, Pisa, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

IntroductionIn patients with Parkinson's disease falling is very common and for this reason, the prosthetic surgical indication in shoulder is reserved for special cases. PD has been linked to several interrelated factors that may contribute to failure of shoulder arthroplasty.Case presentationA 65-year-old woman with PD, severe pain, recurrent bursitis, swelling and functional limitation to all movements in left shoulder presented to our attention. Radiographic and CT exams show cuff-tear arthropathy. The patient was submitted to implantation of a Reverse Shoulder Comprehensive Nano cementless modular system (Biomet(®), Warsaw, IN, USA) with anterosuperior surgical approach. We chose this kind of solution of stemless humeral component after bone mineral consideration.DiscussionReverse shoulder arthroplasty represents an option in the management of glenohumeral arthritis. Poor functional results of RTSA in patients with PD have been attributed to increased muscle tone, severity of tremor and an increased mortality rate. In general, post operative complications related to the humeral component are dominated by fractures (between 1 and 3%): in patients with PD this percentage is higher because of falls often occur. With a stemless implant revisions can be performed easily. Overall, the anterosuperior surgical exposure gives a low risk of postoperative instability.ConclusionIn selected cases of patients with PD, after carefully analysis of bone quality, the use of a stemless component is of benefit in the possible revision cases for periprosthetic fractures and the use of an anterosuperior exposure reduces the percentage of instability. The results obtained about the pain relief are excellent in contrast with functional outcomes that remain poor.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE