Transcranial sonography of the substantia nigra and its correlation with DAT-SPECT in the diagnosis of Parkinson's disease.
Transcranial sonography of the substantia nigra and its correlation with DAT-SPECT in the diagnosis of Parkinson's disease.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Shanghai, CN · Author affiliation
Department of Neurology & Institute of Neurology, Ruijin Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
IntroductionsTranscranial sonography (TCS) of the substantia nigra is a new and promising method to diagnose Parkinson's disease (PD) but its effectiveness is controversial.MethodsAll 55 PD patients involved in the study underwent single photon emission computed tomography (SPECT) imaging using the labeled dopamine transporter radiotracer (99m)Tc-TRODAT-1 to assess nigrostriatal dopaminergic function. The echogenicity of the substantia nigra was measured by TCS in all patients who received DAT-SPECT scanning. Finally, statistical analysis was carried out to determine the diagnostic accuracy of TCS as well as its correlation with (99m)Tc-TRODAT-1 SPECT, its positive predictive value (PPV), and negative predictive value (NPV).ResultsContralateral striatal (99m)Tc-TRODAT-1 uptake was significantly reduced compared to ipsilateral striatal uptake, and had a negative correlation with UPDRS-Ⅲ(r = -0.334, p = 0.013), disease duration (r = -0.393, p = 0.003) and H-Y stage (r = -0.330, p = 0.014). After TCS measurement, the contralateral SN echogenic area was similar to the ipsilateral SN echogenic area (27.77 ± 13.19 vs 25.98 ± 11.94 mm(2), p = 0.402, n = 24). No correlation was identified between TCS and UPDRS-Ⅲ (r = 0.383, p = 0.065), disease duration (r = 0.371, p = 0.075) or H-Y stage (r = 0.259, p = 0.222). The sensitivity and specificity of SN TCS for the diagnosis of PD were calculated as 64.70% and 60% according to DAT-SPECT, respectively, while the positive predictive value and negative predictive value was calculated as 91.67% and 20%, respectively.ConclusionsCompared to DAT-SPECT, TCS is a non-radioactive and convenient procedure to perform. In our investigation, TCS had no correlation with DAT-SPECT. However, the high positive predictive value of TCS highlights its possible utility as a routine diagnostic test.