RESEARCH / DISCOVERY
← Back to the library

Comparison of I-123 MIBG planar imaging and SPECT for the detection of decreased heart uptake in Parkinson disease.

Comparison of I-123 MIBG planar imaging and SPECT for the detection of decreased heart uptake in Parkinson disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Incheon, KR · Author affiliation

Department of Radiology, College of Medicine, Incheon St Mary's Hospital, The Catholic University of Korea, 56, Dongsu-ro, Bupyeong-gu, Incheon, 403-720, South Korea.
Location evidence

Seoul, KR · Author affiliation

Department of Neurology, College of Medicine, The Catholic University of Korea, 505, Banpo-dong, Seocho-gu, Seoul, 137-701, South Korea. siuy@catholic.ac.kr.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Decreased myocardial uptake of I-123 metaiodobenzylguanidine (MIBG) is an important finding for diagnosis of Parkinson's disease (PD). This study compared I-123 MIBG SPECT and planar imaging with regard to their diagnostic yield for PD. 52 clinically diagnosed PD patients who also had decreased striatal uptake on FP-CIT PET/CT were enrolled. 16 normal controls were also included. All underwent cardiac MIBG planar scintigraphy and SPECT separately. Myocardial I-123 MIBG uptake was interpreted on planar and SPECT/CT images separately by visual and quantitative analysis. The final diagnosis was made by consensus between two readers. Kappa analyses were performed to determine inter-observer agreement for both methods. Sensitivity, specificity, and accuracy were compared with McNemar's test. The sensitivity, specificity, and accuracy were 84.6, 100, and 88.2% for planar images and 96.2, 100 and 97.1% for SPECT, respectively, with a significant difference between the two imaging methods (p < 0.031). All inter-observer agreements were almost perfect (planar scintigraphy: κ = 0.82; SPECT: κ = 0.93). Heart-to-mediastinum ratios from PD patients with negative planar and positive SPECT scans (group A) and patients with positive planar and positive SPECT scans (group B) were 1.69 ± 0.16 (1.59-1.85) and 1.41 ± 0.15 (1.20-1.53), respectively, and showed significant difference (p = 0.023). Lung-to-mediastinum ratios for groups A and B were 2.16 ± 0.20 (1.96-2.37) and 1.6 ± 0.19 (1.3-1.78), respectively, and were significantly higher in the former (p = 0.001). I-123 MIBG SPECT has a significantly higher diagnostic performance for PD than planar images. Increased lung uptake may cause false-negative results on planar imaging.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE