RESEARCH / DISCOVERY
← Back to the library

Objective assessment of postural stability in Parkinson's disease using mobile technology.

Objective assessment of postural stability in Parkinson's disease using mobile technology.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

US · Author affiliation · country only

Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BackgroundA significant gap remains in the ability to effectively characterize postural instability in individuals with Parkinson's disease. Clinical evaluation of postural declines is largely subjective, whereas objective biomechanical approaches are expensive and time consuming, thus limiting clinical adoption. Recent advances in mobile devices present an opportunity to address the gap in the quantification of postural stability. The aim of this project was to determine whether kinematic data measured by hardware within a tablet device, a 3rd generation iPad, was of sufficient quantity and quality to characterize postural stability.MethodsSeventeen patients and 17 age-matched controls completed six balance conditions under altered surface, stance, and vision. Simultaneous kinematic measurements were gathered from a three-dimensional motion capture system and tablet.ResultsThe motion capture system and tablet provided similar measures of stability across groups. In particular, within the patient population, correlation between the two systems for peak-to-peak, normalized path length, root mean square, 95% volume, and total power values ranged from 0.66 to 1.00. Kinematic data from five balance conditions--double-leg stance with eyes open on a foam surface, double-leg stance with eyes closed on firm and foam surfaces, and tandem stance on firm and foam surfaces--were capable of discriminating patients from controls.ConclusionsThe hardware within the tablet provides data of sufficient accuracy for the quantification of postural stability in patients with Parkinson's disease. The objectivity, portability, and ease of use of this device make it ideal for use in clinical environments lacking sophisticated biomechanical systems.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE