RESEARCH / DISCOVERY
← Back to the library

Molecular Imaging of PDE10A Knockout Mice with a Novel PET Radiotracer: [(11)C]T-773.

Molecular Imaging of PDE10A Knockout Mice with a Novel PET Radiotracer: [(11)C]T-773.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Stockholm, SE · Author affiliation

Center for Psychiatric Research, Department of Clinical Neuroscience, Karolinska Institutet, SE-171 76, Stockholm, Sweden, miklos.toth@ki.se.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Purpose[(11)C]T-773 is a new radioligand for positron emission tomography (PET) targeting the phosphodiesterase 10A enzyme (PDE10A). PDE10A is highly expressed in the striatum by medium spiny neurons, and it has been demonstrated to be involved in the regulation of striatal signaling through the reduction of medium spiny neuronal sensitivity towards glutamatergic excitation. PDE10A is associated with Parkinson's disease and different neuropsychiatric disorders such as Huntington's disease, obsessive-compulsive disorders (OCD) and schizophrenia. Studies have indicated that the inhibition of PDE10A may represent a novel therapeutic approach to the treatment of the aforementioned diseases characterized by the reduced activity of medium spiny neurons. An appropriate PET radioligand for PDE10A would help to facilitate drug development and drug evaluation.ProceduresWe have evaluated the [(11)C]T-773 ligand in PDE10A knockout mice (heterozygous [HET] and homozygous [HOM]) as well as in normal control animals (WILD) with PET.ResultsThe regional percent standardized uptake values (%SUV; mean ± SD) in the striatum were 48.2 ± 1.0 (HOM), 63.6 ± 5.3 (HET) and 85.1 ± 6.3 (WILD). Between each animal group the striatal %SUV values were significantly different (p < 0.0001). The striatal BPND values (mean ± SD) were 0.0 ± 0.0 (HOM), 0.14 ± 0.07 (HET) and 0.56 ± 0.15 (WILD). The BPND values were significantly lower in homozygous and heterozygous animals compared to wild type (p < 0.0001).ConclusionsThe novel PDE10A radioligand [(11)C]T-773 shows increased signals with higher levels of PDE10A and acceptable binding in the striatum in control animals compared to knockout mice.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE