Adapted step length estimators for patients with Parkinson's disease using a lateral belt worn accelerometer.

Adapted step length estimators for patients with Parkinson's disease using a lateral belt worn accelerometer.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Vilanova i la Geltrú, ES · Author affiliation

Technical Research Centre for Dependency Care and Autonomous Living, Rambla de l'Exposicio, Vilanova i la Geltru, Spain.
Location evidence

Galway, IE · Author affiliation

School of Engineering and Informatics of National University Ireland Galway, Galway, Ireland.
Location evidence

ES · Author affiliation · country only

Clinical Research Unit, Consorci Sanitari del Garraf, Vilanova i~la Geltrú, Spain.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BackgroundParkinson's disease (PD) is a neurodegenerative disease that predominantly alters patients' motor performance. Reduced step length and inability of step are important symptoms associated with PD. Assessing patients' motor state monitoring step length helps to detect periods in which patients suffer lack of medication effect.ObjectiveEvaluate the adaption of existing step length estimation methods based on accelerometer sensors to a new position on left lateral side of waist in 28 PD patients.MethodsIn this paper, a user-friendly position, the lateral side of the waist, is selected to place a tri-axial accelerometer. A newly developed step detection algorithm - Sliding Window Averaging Technique (SWAT) is evaluated in detecting steps using signals from this location. The detected steps are then used to estimate step length using four proposed correction factors for Zijlstra's, Gonzalez's and Weinberg's methods that were originally developed for the signals from lower back.ResultResults obtained from 28 PD patients are discussed and the effects of calibrating in each motor state are compared. A generic correction factor is also proposed and compared with the best method to use instead of individual calibration. Despite variable gait speed and different motor state, SWAT achieved overall accuracy of 96.76% in step detection. Among the different step length estimators, the Zijlstra method performs better with multiplying individual correction factors that consider left and right step length separately providing average error of 0.033 m.ConclusionsZijlstra's method with individual correction factor that considers left and right step length separately and obtained from during ON state of a PD patients provide most accurate estimation among the others. As training session is during ON state, data from induced OFF state to train the methods are not required. A generic correction factor is also proposed to apply with Zijlstra's method to avoid individual calibration process.