Wearability assessment of a wearable system for Parkinson's disease remote monitoring based on a body area network of sensors.

Wearability assessment of a wearable system for Parkinson's disease remote monitoring based on a body area network of sensors.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Universidad, ES · Author affiliation

Life Supporting Technologies, Universidad Politécnica de Madrid, Avenida Complutense 30, Madrid 28040, Spain. jcancela@lst.tfo.upm.es.
Location evidence

Madrid, ES · Author affiliation

Life Supporting Technologies, Universidad Politécnica de Madrid, Avenida Complutense 30, Madrid 28040, Spain. jcancela@lst.tfo.upm.es.
Location evidence

Ioánnina, GR · Author affiliation

Unit of Medical Technology and Intelligent Information Systems, Dept. of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece. atzallas@cc.uoi.gr.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Wearable technologies for health monitoring have become a reality in the last few years. So far, most research studies have focused on assessments of the technical performance of these systems, as well as the validation of the clinical outcomes. Nevertheless, the success in the acceptance of these solutions depends not only on the technical and clinical effectiveness, but on the final user acceptance. In this work the compliance of a telehealth system for the remote monitoring of Parkinson's disease (PD) patients is presented with testing in 32 PD patients. This system, called PERFORM, is based on a Body Area Network (BAN) of sensors which has already been validated both from the technical and clinical point for view. Diverse methodologies (REBA, Borg and CRS scales in combination with a body map) are employed to study the comfort, biomechanical and physiological effects of the system. The test results allow us to conclude that the acceptance of this system is satisfactory with all the levels of effect on each component scoring in the lowest ranges. This study also provided useful insights and guidelines to lead to redesign of the system to improve patient compliance.