RESEARCH / DISCOVERY
← Back to the library

A new HILIC-MS/MS method for the simultaneous analysis of carbidopa, levodopa, and its metabolites in human plasma.

A new HILIC-MS/MS method for the simultaneous analysis of carbidopa, levodopa, and its metabolites in human plasma.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Curitiba, BR · Author affiliation

Department of Pharmacy, Universidade Federal do Paraná, Curitiba, Paraná, Brazil.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Monitoring of the plasmatic levels of levodopa (LEV) and carbidopa (CAR) is necessary to adjust the dose of these drugs according to the individual needs of Parkinson's disease patients. To support drug therapeutic monitoring, a method using HILIC mode and LC-MS/MS was developed for the simultaneous determination of carbidopa, levodopa, and its metabolites (3-o-methyldopa (3-OMD) and dopamine (DOPA)) in human plasma. A triple quadrupole mass spectrometry was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. After straightforward sample preparation via protein precipitation, an Atlantis HILIC (150 × 2.1 mm, 3 μm, Waters, USA) column were used for separation under the isocratic condition of acetonitrile/water (79:21, v/v) containing 0.05% formic acid and 3 mmol/L ammonium formate and the total run time was 7 min. Deuterated LEV was used as internal standard for quantification. The developed method was validated in human plasma with a lower limit of quantitation of 75 ng/mL for LEV, 65 ng/mL for CAR and 3-OMD, and 20 ng/mL for DOPA. The calibration curve was linear within the concentration range of 75-800 ng/mL for LEV, 65-800 ng/mL for CAR and 3-OMD, and 20-400 ng/mL for DOPA (r>0.99). The assay was accurate and precise, with inter-assay and intra-assay accuracies within ±13.44% of nominal and inter-assay and intra-assay precision≤13.99%. All results were within the acceptance criteria of the US FDA and ANVISA guidelines for method validation. LEV, CAR, 3-OMD and DOPA were stable in the battery of stability studies, long-term, bench-top, autosampler, and freeze/thaw cycles. Samples from patients undergoing treatment were analyzed, and the results indicated that this new method is suitable for therapeutic drug monitoring in Parkinson's disease patients.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE